Multi-Drop Multiplexer w/Virtual Channel Mapping - TC2850
Quick Product Search:
TC2850
Multi-Drop Fiber Multiplexer w/Virtual Channel Mapping
Intended for self-healing ring topologies in SCADA, Traffic Control, Process Control & Oil & Gas networks, the TC2850 Multi Drop Fiber Optic Multiplexer features the benefits of Virtual Channel Mapping. It supports RS232, RS422 & RS485 (2/4-wire) electrical interfaces.
Channel Mapping enables users to configure specific channels from the Master to designated Slave units on a fiber ring network. For example, it provides two independent communications networks within one self-healing ring topology, enables cost savings through flexible channel configurations and supports faster polling rates.
The TC2850 is ideal for virtual point-to-point configurations, such as a dedicated telephone circuit, within a redundant or self-healing ring network. It is also used in larger networks with multiple port SCADA Host Controllers to speed up polling times.
Features
- Virtual Channel Mapping (VCM) Enables Concurrent Applications, Cost-Saving Benefits & Reduces Polling Time
- Sophisticated Self-Healing Ring
- All Digital Design
- Hardened Temperature version exceeds NEMA & CALTRANS specs
- Protocol Transparent
- RS-232, RS-422, RS-485 (2/4-wire)
- Data rates up to 120 Kbps
- Multimode (1300nm) or Single Mode (1300/1550nm)
- Built-In Power Redundancy
- Optical Loop Integrity Test
- Local Dry Contact Alarm Relay
- Rackmount or Standalone
Applications
Because the TC2850 effectively
enables two independent communications
networks in one self-healing
ring topology, it can be used to run
multiple applications concurrently.
For example, it enables virtual pointto-
point configurations, such as a
dedicated telephone circuit, within a
Self-Healing Ring network (See diagram
on back page).
It is also used in larger networks, with
multiple port SCADA Host Controllers,
to speed up polling times. Typical
application environments include
SCADA, Traffic Control, Process
Control, Security, Oil & Gas, and
Energy Management.
Specifications
Data Rates
- Async RS-232, RS-422, RS-485up to 120 Kbps*
Optical
- TransmitterLED/ELED/LASER*
- ReceiverPIN Diode
- Wavelength1300nm MM, 1300/1550nm SM
- Fiber Optic ConnectorsST, Optional FC
- Loss Budget * - 1300/1550nm
- Multimode @62.5/125µm15dB
- Single Mode @9/125µm20dB
Electrical
- Phone ConnectorRJ11 Female
- InterfaceRS-232, RS-422, or RS-485 (2 or 4-wire)
Diagnostic Functions
- Local & Remote Loopback, Signal Generator, Disable Alarm,Yes
- Enable Anti-Streaming (TC2851)Yes
Power
- Standard12VDC @ 500mA
- Optional24VDC or 115/230VAC with Power Cube
System
- Bit Error Rate1 in 109 or Better
Alarm
- Dry ContactNormal OPEN
Visual Indicators
- System PWR A, PWR B, VccA, VccB
- Electrical SignalBRD & RSP (for each channel), AST (TC2851 only)
- Optic SignalRxA, TxB, RxB, SYNCA, SYNCB, A2B (TC2851
only), B2A (TC2851 only), LPA, LPB
- AlarmPWRA, PWRB, OPTIC, AST (TC2851 only)
Temperature
- Operating-10°C to 50°C
- Hi-Temp1 (optional)-20°C to 70°C
- Hi-Temp2 (optional)-20°C to 80°C
- Storage-40°C to 90°C
- Humidity95% non-condensing
Physical (Rackmount Unit)
- Height(6.71 cm) 2.64"
- Width(18.13 cm) 7.14"
- Depth(24.89 cm) 9.80"
- Weight(1.20 kg) 2.66 lbs
* Contact factory for higher requirements