Self-Healing Ring Multi-Drop Fiber Optic Multiplexer
w/ Virtual Channel Mapping

(Model TC2850/51/52)
Related Products:
TC2100, TC2200, TC2400, TC2800, TC2900, TC3720

  • Virtual Channel Mapping (VCM) Enables Concurrent Applications, Cost-Saving Benefits & Reduces Polling Time
  • Sophisticated Self-Healing Ring
  • All Digital Design
  • Hardened Temperature version exceeds NEMA & Caltrans Specs
  • Protocol Transparent: ModBus, DNP3, Telegyr, etc...  
  • Async Data Rates up to 120 Kbps
  • Multimode & Single Mode (1300/1550nm)
  • 4, 8 or 12 Channels RS-232/422/485
  • Built-In Power Redundancy
  • Local Dry Contact Alarm Relay
  • Rackmount or Standalone
  • Extend telephone lines with TC1900 RS-232 or Fiber Phone Extenders
Data Sheets, TC2850/51: being revised
Data Sheets, TC2850/52: being revised
 


(Click on image to enlarge)

 
  Talk to a sales engineer on this product/application.


Applications

The TC2850 is often used for applications requiring virtual point-to-point configurations, such as a dedicated telephone circuit, within a Self-Healing Ring network. It is also used in larger networks with multiple port SCADA Host Controllers to speed up polling times. Typical application environments include SCADA, Traffic Control, Process Control, Security, Oil & Gas, and Energy Management.


Description           

The TC2850 Fiber Optic Self-Healing Ring Multiplexer features the potential benefits of Channel Mapping:

  • Two independent communications networks(e.g. SCADA networks) in one self-healing ring topology

  • Cost savings through flexible channel configurations

  • Faster polling rates.

Channel Mapping enables users to configure specific channels from the Master (Model TC2850) to designated Slave units (Model TC2851 & TC2852) on a fiber ring. Designated channels could include both a dedicated virtual point-to-point channel and a broadcast poll-response channel on each Slave.

The TC2850 offers a sophisticated Self-Healing Ring scheme and is available with dual masters for maximum reliability.  Fault conditions are detected both Tx and Rx, upstream and downstream of each unit, and automatically re-routed to maintain Ring integrity.  Dry contact alarms can be connected to RTUs/PLCs to help pinpoint the location of a fault.

It is transparent to all protocols, supports data rates up to 120 Kbps and is compatible with RS-232, RS-422 or RS-485 (2- or 4-wire) interfaces over single mode or multimode fiber.  Options include Hardened Temperature versions (-20°C to 70°C & -40°C to 80°C) for extreme environments and Conformal Coating to prevent corrosion, etc.

The Master (TC2850) and Slave (TC2851 & TC2852) units each have two pairs of fiber optic ports, one primary and one secondary.  On the electrical side, the Master(s) can have 4, 8 or 12 ports. The TC2851 Slave has four RJ11 ports providing four independent channels. Optical signals are regenerated at each Slave (drop). Each TC2852 Slave has two pairs of RJ11 ports providing two independent, redundant channels.

The TC2850 is compatible with all popular types and sizes of fiber optic cable.  Fiber connectors are ST or FC.  Electrical connectors are RJ11 female.  Standard power is 12VDC.  Optional power sources are 24VDC, 125VDC or 115/230VAC with an external power cube.

Top


Technical Specifications    

Data Rates
RS-232/422/485 Async Up to 120 Kbps
Optical
Transmitter ELED, LASER*
Receiver PIN Diode
Wavelength 1300nm Multimode
1300nm, 1550nm Single Mode
Fiber Optic Connectors ST, SC or FC
Loss Budget*
(1300nm, 1550nm)
Multimode (62.5/125µm): 15dB
Single Mode (9/125µm): 20dB
Electrical
Connector RJ11 Female
Interface RS-232, RS-422, or RS-485 (2 or 4 wire)
System
Bit Error Rate 1 in 109 or better
Diagnostic Functions
Local & Remote Loopback, Signal Generator, Disable Alarm, Enable Anti-Streaming (TC2851,TC2852)

* Contact factory for higher requirements
Alarm
Dry Contact Normal OPEN
Visual Indicators
System Status PWR A, PWR B, VccA, VccB
Electrical Signal Status BRD, RSP (for each channel)
Optical Signal Status TxA, RxA, TxB, RxB, SYNC A, SYNC B, A2B, B2A, LPA, LPB, ALARM
Power
Standard 12VDC @ 800mA
Optional 24VDC, -48VDC, 125VDC or 115/230VAC (w/external power pack)
Temperature
Operating -10° to 50°C
Hi-Temp1 (optional) -20° to 70°C
Hi-Temp2 (optional) -40° to 80°C
Storage -40° to 90°C
Humidity 95% non-condensing
Physical (Standalone/Wallmount Unit) (Details)
Height (6.71 cm) 2.64"
Width (18.13 cm) 7.14"
Depth (24.89 cm) 9.80"
Weight (1.4 kg) 4 lbs.

Top


Information Request Form                

Select the items that apply, and then let us know how to contact you.

Send product literature      Model:  
Have a salesperson contact me

      Name: 
     Title: 
   Company: 
   Address: 
    E-mail: 
     Phone: 
       FAX: 
  Comments: 
I Initially heard of TC Communications from:

  Google.com
  Yahoo.com
  MSN.com
  AOL.com
  Referral
  Magazine

  Other

                                 Top


© 2007, TC Communications, Inc.  All rights reserved.
17881 Cartwright Road - Irvine, CA 92614, info@tccomm.com
Tel:(949)852-1972, Sales:(800)569-4736 
Fax:(949)852-1948, sales@tccomm.com

Page Last Updated: 03/25/2008